Bid Opportunity: Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.

Customer Login

Government Bid Opportunity

Title:

Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.

Category: Z - Maintenance, Repair or Alteration of Real Property

Get Started   

To view similar Open Bids we recommend the Federal, State & Local package.

Bid Details

     
Type:   Bid
Agency Type:   Federal
State:   Florida
Date Entered:   07/06/2022
Due Date:   07/08/2022
Agency:   VETERANS AFFAIRS, DEPARTMENT OF, FL
Description:   Request for Information and Government Responses for Solicitation Number: 36C24822R0102 FY22 NRM TIER 2 (PROJ 672-22-604) DB Replace Facility Main Feeders at VACHS, San Juan, PR 00921-3201:Does the feeder s replacement include the grounding conductor also?Government Responses:Yes, the feeders consist of 3 live cables, including a ground conductor. The ground conductors need to be replaced also. The grounding conductor is essential part of the electrical system of the feeders, in accordance with Specification 26 05 13 Medium-Voltage Cables paragraph 1.2. located in page 1 of 11 pages as shown in referenced subparagraph A. Section 26 05 11 A and Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS: Requirements that apply to all sections of Division 26. Subparagraph B. Section 26 05 26, GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS: Requirements for personnel safety and to provide a low impedance path for possible ground fault currents. Also, this requirement is in provided Scope of Work (SOW), paragraph 2.f. located in page 10 of 90 pages: All electrical equipment and components associated with the feeder s replacement shall be furnished by D-B Team including new splices and miscellaneous electrical equipment if necessary. The project will include the following, in accordance with the SOW, Section 2, paragraph a located in page 10 of 90 pages: Replacement of all normal power feeders form the main substation to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of each feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility. Also, with the SOW, Section 2, paragraph d. Replacement of all standby power feeders from paralleling switch gear to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of the feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility and stand by power capability.
248-NETWORK CONTRACT OFFICE 8 (36C248) Department of Veterans Affairs No. Florida/So. Georgia Health Care System 33637 8875 HIDDEN RIVER PARKWAY TAMPA FL 33637 Rey F Clemente, Contract Specialist, Email rey.clemente@va.gov
RFP Number:   36C24822R0102
Bid Documents:   Download Document
The official solicitation bid document(s) posted by the agency, often including detailed specifications, requirements, forms and directions necessary for bid submission.
     
Most popular bid categories:
Construction bids, Architectural and Engineering bids, Grounds and Landscaping bids, IT/Technology Consulting bids, Janitorial and Cleaning bids, Security and Safety bids, View all categories
Most popular bidding states:
California bids, Texas bids, Florida bids, Massachusetts bids, Georgia bids, New Jersey bids, North Carolina bids, New York bids, View all regions

Help Navigation

About GovernmentBids.com | Alternative To FBO | Help | Watch Overview | Site Map | Legal Notice | Privacy Policy | Terms & Conditions

Copyright © GovernmentBids.com - All rights reserved.